Checklist for Installation Tolerances
S. No | Description | Tolerance |
1 | Position on plan or vertical surface | ± 3 mm |
2 | Deviation in alignment | Not more than 1 in 300 |
3 | Deviation in level (horizontal) | Not more than 1 in 300 |
4 | Deviation in plumb (vertical) | Not more than 1 in 800 |
5 | Offset in alignment of adjoining surfaces | ± 0.5 mm |
6 | Offset in alignment of separated surfaces | ± 1.5 mm |
7 | Bracket fixing tolerance | Not more than 1 mm |